REACTIVE POWER COMPENSATION WITH THE HELP OF VOLTAGE CONTROLLED D-STATCOM
Abstract
In this paper new method for voltage controlled mode of D-STATCOM will used for reference voltage generation while in traditional method of VCM (voltage controlled mode) reference voltage will taken as 1 p.u. In this new method it is possible to achieve unity power factor at load terminal which is not possible in traditional method. Also, loss in the new method will less as compare to traditional method. This is due to more current supplied by compensator in traditional method as compared to new method. In both the method D-STATCOM each phase will contain three capacitor for removing high switching frequency. Also, it is possible to clear sag for more time as compare to traditional method. Through detailed simulation and experimental results, it will found that load will not affected due to sag & also possible to achieve UPF in new method.
Full Text:
PDFReferences
Chandan Kumar, and Mahesh Kumar. Mishra, “A voltage controlled DSTATCOM for power quality improvement”, IEEE transactions on power delivery, vol 29, no-3, june 2014,pp 1499-1507.
Mahesh K. Mishra ArindamGhosh, and Avinash Joshi, “Operation of a DSTATCOM in voltage control mode,” IEEE Trans. Power Del., vol. 18, no. 1, pp. 258–264, Jan. 2003.
Bhim Singh and Sabha Raj Arya,“Back-Propagation Control Algorithm for Power Quality Improvement Using DSTATCOM”,IEEE TRANSACTIONS on Industrial Electronics, VOL. 61, NO. 3, march 2014,pp 1204 - 1212.
P. Mitra and G. Venayagamoorthy, “An adaptive control strategy for DSTATCOM applications in an electric ship power system,” IEEETrans. Power Electron., vol. 25, no. 1, pp. 95–104, Jan. 2010.
Avinash. Joshi, and H. M. Suryawanshi, “A novel method of load compensation under unbalanced and distorted voltages,” IEEE Trans. Power Del., vol. 22, no.1, pp. 288–295, Jan. 2007
G.Yalienkaya, M.H.J Bollen, P.A. Crossley, “Characterization of Voltage Sags inIndustrialDistributionSystem”,IEEE transactions on industry applications, volume 34, No. 4, July/August, PP.682- 688, 1999.
AElnady, M Salama. Unified approach for mitigating voltage sag and voltage flicker using the DSTATCOM. IEEE Trans Power Del. 2006; 20(2): 992-1000.
B. Singh, P. Jayaprakash, T. Somayajulu, and D. Kothari, “Reduced rating VSC with azig-zag transformer for current compensation in a three-phase four-wire distribution system,” IEEE Trans. Power Del., vol. 24, no. 1, pp. 249–259, Jan. 2009 .
ParagNijhawan, Ravinder Singh Bhatia, Dinesh Kumar Jain, “Role of DSTATCOM in a power system network with induction furnace load” IEEE 5th Power India Conference, Dec.19-22, 2012.
Naresh K. Kummari, Asheesh K Singh and Pradeep Kumar, “Comparative Evaluation of DSTATCOM Control Algorithms for Load Compensation”, IEEE 15th International Conference on Harmonics and Quality of Power (ICHQP), pp:299-306, 2012.
SaiKiran Kumar Sivakoti, Y. Naveen Kumar and D.Archana, “Power Quality Improvementi in Distribution System Using D-Statcom In Transmission Lines”, IJERA, ISSN: 2248-9622, Vol. 1, Issue 3, pp.748-752,2011.
SaiKiran Kumar Sivakoti, Y. Naveen Kumar and D.Archana, “Power Quality Improvementi in Distribution System Using D-Statcom In Transmission Lines”, IJERA, ISSN: 2248-9622, Vol. 1, Issue 3, pp.748-752in2012..
Roger C. Dugan, Mark F.McGranaghan, Surya Santoso, and H.WayneBeaty,“Electrical Power Systems Quality”, The McGraw-Hill, Second Edition, 2004
Refbacks
- There are currently no refbacks.