Open Access Open Access  Restricted Access Subscription Access

Characteristics of High Pressure Gas in Heat Exchanger

Prof Urmila Sharma

Abstract


In Indian Coal mines, underground mines, mineral ore mines syngases at high pressure and high temperature are determined in huge portions. This syngas is fairly poisonous, harmful and flammable gas so one can be present in environment which may also cause many accidents. Subsequently its miles essential to lessen the content of syngas from mines in the ecosystem. This paper describes literature assessment of Convective heat transfer traits of excessive pressure gas utilized in mines. Heat transfer in convection cooling segment of pressurized coal gasifier with the membrane helical coils and membrane serpentine tubes beneath excessive pressure is studied.

Full Text:

PDF

References


Paisarn Naphon, SomchaiWongwises” A look at of the warmth transfer traits of a compact spiral coil heat exchanger beneath wet surface situations, Fluid Mechanics, Thermal Engineering and Multiphase float research Lab. (destiny), department of Mechanical Engineering,KingMongkut_s college of technology Thonburi,Bangmod, Bangkok 10140, Thailand

D. G. Prabhanjan, G. S. V. Ragbavan and T. J. Rennie” comparison of heat switch fees among a immediately tube heat exchanger andhelically coiled heat exchanger, Depamnti of Agricuhural and Biosystems Engineering Macdonald Campus of McGill college Ste.Ame-de-Bellevue, qc, Canada, H9X 3V9.

Yan Li, Xiumin Jiang *, Xiangyong Huang, JigangJia, Jianhui Tong” Optimization of excessive-strain shell-and-tube warmth exchangerfor syngas cooling in an IGCC, faculty of Mechanical Engineering, Institute of Thermal energy Engineering, Shanghai Jiao Tongcollege, Shanghai 200240, PR China.

SomchaiWongwises, YutasakChokema” Fluid Mechanics, Thermal Engineering and Multiphase waft studies Lab(destiny),department of Mechanical Engineering, King Mongkut’s university of era Thonburi, Bangmod, Bangkok 10140,Thailand The Joint Graduate school of power and environment (JGSEE), King Mongkut’s university of generation Thonburi, Bangmod, Bangkok 10140, Thailand.

H. Taherian, P.L. Allen” Experimental take a look at of herbal Convection Shell-and-Coil warmth Exchangers, vol. 357, ASME-PublicationsLtd.,1998. pp. 31–38.

N. Ghorbani, H. Taherian, M. Gorji, H. Mirgolbabaei” Experimental have a look at of combined convection warmness transfer in vertical helicallycoiled tube heat exchangers, Experimental Thermal and Fluid technology 34 (7) (2010) 900–905.

G. Karahalios” combined convection waft in a heated curved pipe with middle,Physics of Fluids A: Fluid Dynamics 2 (1990) 2164.

A. Figueiredo, A. Raimundo” analysis of the performances of heat exchangers utilized in hot-water shops, carried out ThermalEngineering sixteen (7) (1996) 605–611.

Sparrow EM, Niethammer JE” magazine of warmth switch 1981:103(four):638-45.

M.R. Salimpour” branch of Mechanical Engineering, Isfahan college of technology, Isfahan, 84156-83111, Iran

VimalKumar,SupreetSaini,ManishSharma,okay.D.P.Nigam” department of Chemical Engineering, Indian Institute of technologyDelhi, HauzKhas, New Delhi,India.


Refbacks