Open Access Open Access  Restricted Access Subscription Access

ANALYSIS OF MOISTURE CONTENT IN BRICKS WALL PANEL USING FFT ANALYSER

Pravin B Shinde, Rohan A Ahire, Akshay V Suryavanshi, Rohan S Thakur, Prashant B Dandekar

Abstract


Modal examination is a great instrument to categorize the dynamic features of structure and material. All structures and materials that shake through high largeness of shaking at its own resonant frequency. For improving its strength, it is important to know the modal frequencyresonant frequency, modal figure and curbing features of the structure and material at its changing functioning circumstances and dependability at project point. Such a material in construction industry is brick. Brick is one of the most used structural materials for brick wall masonry, so it is necessary to identify its durability and reliability before use in construction. Water absorption is one of the property of all types of bricks, the allowable water absorption for standard brick, later involvement in the water for 24 hours, must not be more than 20 percent through heaviness of the brick. This system, we are using to measure the water content of brick wall is natural frequency, which is new in field of construction. Natural frequency is the frequency at which a method wavers once not exposed to an incessant or recurrent outside force. The basic idea behind this technology is that modal parameters of brick wall like (geometrical parameters, material properties) are the functions of the physical properties of the brick. Variations in the physical possessions will reason obvious changes in the modal attributes. By use of natural frequency to detect water content will be very useful for onsite detection of moisture.


Full Text:

PDF

References


Liang, Choy et.al.(1991),"Detection Of Cracks In Beams Structures Using Measurements Of Natural Frequencies", "Journal of Franklin institute Pergamum press" vol (0016-0032/91).

Natori, Aoki et.al.(2015),"vibration characteristics of a building structure from a natural frequency point of view" "Journal of ijeraā€¯ vol (5) part 2.

Nandawana, Maiti et.al.(1997),"Detection Of Location And Size Of A Cracks Inn Stepped in Cantilever Beams Based on Measurements Of Natural Frequency", "Journal of sound and vibration" vol (203-3).

Morales, Dominguez et.al.(2013),"non-linear model for conditions monitoring of non-stationery vibration signals in ship drive line applications"," Journal of Elsevier ltd." vol (0888-3270).

Martinez, Rodriguez et.al.(2014),"EEEMD-MUUSIC-based analysis for natural frequencies identifications of structures using artificial and natural excitations", "hindawi publishing corporation " vol (2014,587671).

Prime, Farrar et.al.(1997),"a summary review of vibration-based damage identification methods", "Journal los alamos national laboratory" vol (203)

Yang, Liao et.al.(2014),"Natural Frequency-Based Lines Fault Locations In HVDC Lines", "Journal of IEEE transactions on power delivery" vol (29).

Xu, Guobing et.al.(2014),"A Fault Locations For VSC-HVDC Transmissions Lines Based On Natural Frequency Of Currents", "Journal of Elsevier ltd." vol (0142-0615/2014).

IS 1893, IS 3495(part 1), IS 2212, IS 1077, IS 1905


Refbacks

  • There are currently no refbacks.